System Information: www.remoteme.de (178.254.11.55)

System Übersicht
Zugewiesener Hostname www.remoteme.de
Überwachte IP 178.254.11.55
Kernel Version 4.4.0-108-generic (SMP)
Distro Name  Ubuntu 16.04.4 LTS
Betriebszeit 131 Tage 22 Stunden 16 Minuten
Eingeloggte Benutzer 0
Auslastung 1.60 2.11 2.20

Netzwerk-Auslastung
Schnittstelle Empfangen Gesendet Fehler/Verworfen
lo 18,87 GB 18,87 GB 0/0
eth1 540,29 GB 2433,62 GB 0/0
eth0 14642,49 GB 5831,46 GB 0/0
Hardware Übersicht
Prozessoren 12
Modell Intel(R) Xeon(R) CPU E5-2620 v3 @ 2.40GHz
Taktfrequenz 2,78 GHz
Cachegröße 15,00 MB
System Bogomips 57595.32
PCI Geräte
-Communication controller: Intel Corporation C610/X99 series chipset MEI Controller #1
-Communication controller: Intel Corporation C610/X99 series chipset MEI Controller #2
-(2x) Ethernet controller: Intel Corporation I350 Gigabit Network Connection
-Host bridge: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DMI2
-ISA bridge: Intel Corporation C610/X99 series chipset LPC Controller
-PCI bridge: ASPEED Technology, Inc. AST1150 PCI-to-PCI Bridge
-PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #1
-PCI bridge: Intel Corporation C610/X99 series chipset PCI Express Root Port #7
-PCI bridge: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 PCI Express Root Port 1
-PCI bridge: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 PCI Express Root Port 2
-(3x) PCI bridge: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 PCI Express Root Port 3
-PIC: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 I/O APIC
-Performance counters: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Home Agent 0
-Performance counters: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 PCIe Ring Interface
-(2x) Performance counters: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 R3 QPI Link 0 & 1 Monitoring
-Performance counters: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Scratchpad & Semaphore Registers
-RAID bus controller: LSI Logic / Symbios Logic MegaRAID SAS 2208 [Thunderbolt]
-SATA controller: Intel Corporation C610/X99 series chipset 6-Port SATA Controller [AHCI mode]
-SATA controller: Intel Corporation C610/X99 series chipset sSATA Controller [AHCI mode]
-SMBus: Intel Corporation C610/X99 series chipset SMBus Controller
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Address Map, VTd_Misc, System Management
-(2x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Buffered Ring Agent
-(8x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DDRIO
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DDRIO Channel 0/1 Broadcast
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DDRIO Channel 2/3 Broadcast
-(2x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DDRIO Global Broadcast
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DMA Channel 0
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DMA Channel 1
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DMA Channel 2
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DMA Channel 3
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DMA Channel 4
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DMA Channel 5
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DMA Channel 6
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 DMA Channel 7
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Home Agent 0
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Hot Plug
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Channel 0 ERROR Registers
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Channel 0 Thermal Control
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Channel 1 ERROR Registers
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Channel 1 Thermal Control
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Channel 2 ERROR Registers
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Channel 2 Thermal Control
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Channel 3 ERROR Registers
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Channel 3 Thermal Control
-(4x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Channel Target Address Decoder
-(2x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 0 Target Address, Thermal & RAS Registers
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 1 Channel 0 Thermal Control
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Integrated Memory Controller 1 Target Address, Thermal & RAS Registers
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 PCIe Ring Interface
-(5x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Power Control Unit
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 R3 QPI Link 0 & 1 Monitoring
-System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 RAS, Control Status and Global Errors
-(2x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Scratchpad & Semaphore Registers
-(3x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 System Address Decoder & Broadcast Registers
-(6x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 Unicast Registers
-(2x) System peripheral: Intel Corporation Xeon E7 v3/Xeon E5 v3/Core i7 VCU
-USB controller: Intel Corporation C610/X99 series chipset USB Enhanced Host Controller #1
-USB controller: Intel Corporation C610/X99 series chipset USB Enhanced Host Controller #2
-USB controller: Intel Corporation C610/X99 series chipset USB xHCI Host Controller
-Unassigned class [ff00]: Intel Corporation C610/X99 series chipset SPSR
-VGA compatible controller: ASPEED Technology, Inc. ASPEED Graphics Family
IDE Geräte keine
SCSI Geräte
-LSI MR9271-8i (Direct-Access)
-LSI MR9271-8i (Direct-Access)
USB Geräte
-(2x) Intel Corp.
-(3x) Linux Foundation 2.0 root hub
-Linux Foundation 3.0 root hub
-ATEN International Co., Ltd
-ATEN International Co., Ltd Hub
Speicher-Auslastung
Typ Prozentuale Auslastung Frei Benutzt Größe
Physikalischer Speicher   87% 8,26 GB 54,55 GB 62,81 GB
- Kernel + Anwendungen   37%   23,29 GB  
- Puffer   25%   15,62 GB  
- Cache   25%   15,65 GB  
Auslagerungsdatei   0% 63,64 GB 258,10 MB 63,89 GB
Angemeldete Dateisysteme
Mount Typ Partition Prozentuale Auslastung Frei Benutzt Größe
/ ext4 /dev/sda2  69% (7%) 799,04 GB 1859,81 GB 2686,16 GB
/.backup ext4 /dev/sdb1  56% 1428,57 GB 2052,07 GB 3666,91 GB
/run/lock tmpfs tmpfs  0% (1%) 5,00 MB 0,00 KB 5,00 MB
/run/user/3312 tmpfs tmpfs  0% (1%) 6,28 GB 0,00 KB 6,28 GB
/run/user/4285 tmpfs tmpfs  0% (1%) 6,28 GB 0,00 KB 6,28 GB
/run tmpfs tmpfs  9% (1%) 5,69 GB 601,11 MB 6,28 GB
/sys/fs/cgroup tmpfs tmpfs  0% (1%) 31,41 GB 0,00 KB 31,41 GB
/dev/shm tmpfs tmpfs  0% (1%) 31,41 GB 4,00 KB 31,41 GB
/dev devtmpfs udev  0% (1%) 31,39 GB 0,00 KB 31,39 GB
Insgesamt :    61% 2259,00 GB 3911,89 GB 6384,47 GB

Vorlage:    Sprache: 

Gehe zu RemoteMe Seite
Erstellt von phpSysInfo-2.5.3 am 22.Mai 2018 um 10:18 0,4918 sec